Transformers operate on the principle that every electric field creates a magnetic field, and every magnetic field creates an electrical field. There are many different types of transformers on the market today. Each one serves a different purpose. Miracle Electronics can provide the highest quality transformers. power transformers in India but, it is also a leader transformer manufacturer in India. It doesn't matter what type of transformer you have, it is important to test it to ensure that it works properly.
First, inspect the transformer visually. Don't test the transformer if the transformer's exterior is bulgy or has any burn marks. Overheating is a common cause of transformer failure. You can test the transformer if it appears to be in good condition. You must first determine the wiring configuration of the transformer. To understand the connections of the transformer, you will need a schematic. You can find the schematic in the product documentation, or on the website for the circuit manufacturer.
Next, identify the inputs & outputs of your transformer. The primary transformer will have the electrical circuit that generates the magnet field. The secondary circuit will receive power from the magnetic fields.
Next, you need to determine the output filtering. To transform the AC power into DC power, you can attach capacitors or diodes to your transformer secondary. The schematic will show the filtering and shaping.
Next, prepare to measure the circuit voltages. To gain access to the circuit you will need to remove any covers or panels. To measure the voltage, you can use a digital multimeter that is available at electrical supply shops. Use the AC mode of the digital multimeter to measure the transformer primary. If the voltage measured is less than 80%, it could be a fault in the circuit or the transformer. If this happens, it is best to separate the input and primary circuits. If the input power is below the expected value, then it indicates that the primary circuit is defective. If the input power is not at the expected level, it means that the fault is in the input circuit.
Use the AC mode of your digital multimeter if there is no shaping or filtering in the secondary circuit. If there is shaping or filtering, you can use the DC scale. If the secondary voltage does not match the expected voltage, it is likely that the transformer or the filtering/shaping components are at fault. To make a decision, it is important to test each filtering and shaping component separately. If the testing is negative, the transformer may be defective.